St Andrews House West Street Woking Surrey GU21 6EB
Refused on 12 June 2026
Council decision: Prior Approval - Refused6 reasons for refusal
Proposal
Application for prior approval under Part 20, Class AA of Schedule 2 of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) for construction of one additional storey above the existing commercial building to provide 11 flats and cycle storage.
- Submitted
- 20 April 2026
- Council
- Woking Borough Council
- ReceivedSubmitted20 Apr
- ValidatedValidated20 Apr
- Consult.Consultation
- TargetTarget Date
- DecidedDecided12 Jun
Decided in 53 days
About this application
This is a planning application at St Andrews House West Street Woking Surrey GU21 6EB. Woking has handled 3,266 applications of this type. This one was decided in 53 days, 3 days quicker than Woking's typical decision time. The site is in 2 listed buildings nearby. There has been 1 other application at this address. We hold 1,569 applications in total for the GU21 postcode area.
Why it was refused
- It has not been demonstrated that St Andrews House is a detached building as set out in Schedule 2, Part 20, Class A of the Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). The proposal does not, therefore, benefit from the permitted development right conferred by that Part.
- Permission to use the building as residential dwellinghouses was granted only by virtue of Class MA of Part 3 of this Schedule by application PLAN/2024/0900. The wording of criterion AA.1(za) refers only to the granting by virtue of Class MA of Part 3 of this Schedule and therefore, this restriction has been activated by application PLAN/2024/0900. The proposal therefore fails to comply with AA.1(za) of Part 20, Class AA of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended).
- The additional storeys proposed at fourth floor level (i.e., the element containing residential units referenced as 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 11) would not be constructed immediately above the topmost storey or be constructed other than on the principal part of the building, as this is defined at 'Interpretation of Part 20' (C)(1). The additional storey would be constructed on front and side extensions of a lower height (i.e., of three storey height). Therefore, the proposal fails to comply with AA.1 and AA.1 (d) of Part 20, Class AA of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended).
- The applicant has failed to sufficiently and accurately demonstrate that the proposed development would not give rise to a significant harmful loss privacy to properties within Town Gate House (extant prior approvals PLAN/2025/0769 and PLAN/2026/0130). Furthermore, the proposed development would, by reason of the resulting height, bulk, proximity and addition of south-facing residential windows at fourth storey level, give rise to an undue sense of enclosure and overbearing effect, and loss of privacy, to the habitable rooms which would be significantly harmful to existing and future occupiers of Town Gate House. The proposed development is therefore contrary to paragraph AA.2.(1)(g) of Part 20, Class AA of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) and Section 12 of the National Planning Policy Framework (NPPF) (2024) (particularly paragraph 130).
- In the absence of a Noise Impact Assessment, it has not been demonstrated that the impacts of noise from any commercial premises would not be detrimental to the on the intended occupiers of the new dwellinghouses and their living conditions contrary to Paragraphs AA.2(h) of Class AA, Part 20, Schedule 2 of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) and the National Planning Policy Framework (2024).
- On the basis of the submitted drawings, when measured (in accordance with paragraph (7), of article 9A (fire statements) of the Town and Country Planning (Development Management Procedure) (England) Order 2015) from ground level to the top floor surface of the top storey of the building (ignoring any storey which is a roof- top machinery or plant area or consists exclusively of machinery or plant rooms), would measure 18 metres or more in height. As such the development meets the fire risk condition and the applicant has failed to submit any information relating to the external wall construction of the existing building nor in respect of the fire safety impacts on the intended occupants of the building. The proposed development is therefore contrary to paragraph AA.2.(1)(k) and(l) of Part 20, Class AA of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended).
From the council's decision notice.
Application details
- Postcode
- GU21 6EB
Planning application dates
- Date validated
- 20 April 2026
Site constraints
Designations that overlap or adjoin the site outline.
- Flood zone 1: Low probability (rivers and sea)
Not published by this council, so not checked: Article 4 directions and tree preservation orders. Ask the council if these matter.
Also checked, none recorded (22)
flood storage areas, conservation areas, listed buildings, green belt, scheduled monuments, World Heritage Sites, World Heritage Site buffer zones, registered parks and gardens, registered battlefields, Heritage at Risk entries, nutrient neutrality catchments, national parks, National Landscapes, SSSIs, Special Areas of Conservation, Special Protection Areas, Ramsar sites, ancient woodland, national nature reserves, local nature reserves, heritage coasts and brownfield registers.
A guide only, from official open data; it is not a planning search. Flood zones cover rivers and sea, not surface water.
Data © Crown copyright and others · sources and licences
Contains public sector information from planning.data.gov.uk (MHCLG and local planning authorities), licensed under the Open Government Licence v3.0. © Crown copyright and database right 2026.
© Historic England 2026. Contains Ordnance Survey data © Crown copyright and database right 2026. The Historic England GIS Data contained in this material was obtained on 2026-11-03. The most publicly available up to date Historic England GIS Data can be obtained from HistoricEngland.org.uk.
© Natural England copyright. Contains Ordnance Survey data © Crown copyright and database right 2026.
© Environment Agency copyright and/or database right 2026. All rights reserved. Flood Map for Planning, Open Government Licence v3.0.
Contains Ordnance Survey data © Crown copyright and database right 2026.
Source: Office for National Statistics licensed under the Open Government Licence v.3.0. Contains OS data © Crown copyright and database right 2026.
Planning history at this site
1 other application at this property, newest first.
Source: Woking
Track this application
Get email alerts when there is a planning decision or status change.
Get email alerts near GU21
New planning applications delivered to your inbox daily.
Around this site
Nearby applications
- Land Adjacent To St Andrews House Gloucester Square Woking SurreyPLAN/2024/0048 · FullRefused0.0 mi
- Barclays Town Gate House Church Street East Woking Surrey GU21 6AEHABREG/2025/0004Approved0.0 mi
- Barclays Town Gate House Church Street East Woking Surrey GU21 6AEPLAN/2026/0130 · OutlineApproved0.0 mi
- The Ambassadors Victoria Way Woking SurreyPLAN/2025/0786 · AdvertisingApproved0.0 mi
- The Ambassadors Victoria Way Woking SurreyPLAN/2025/0726 · AdvertisingApproved0.0 mi
For applicants and trades
Contractors near this project
Find contractors for commercial fit-out near this site- Elite Paving GroupVerifiedAscotLandscaping & Driveways7.8 mi
- Ultimate IES LtdElectrician0.1 mi
- Specialist Leak Detection LtdWoking0.1 mi
- Angel Electrical LtdElectrician0.1 mi
Planning something similar?
See what the council approved and refused for new homes on your street. Pick your home and get the evidence before you pay for drawings.